The SCR-AD Series Refrigerated Air Dryer uses a cooling process to condense water vapor in compressed air into liquid droplets, which are then separated and discharged through a gas-water separator — reducing moisture in the compressed air system, preventing corrosion, extending the service life of downstream equipment, and maintaining consistently dry air quality.

Key Features
- Energy-saving — Adopts an integrated three-in-one aluminum alloy heat exchanger and enlarged pre-cooling reheater design, minimizing process loss of cooling capacity and enhancing cold energy recycling.
- High efficiency — Flow guide fins inside the integrated heat exchanger ensure uniform heat exchange of compressed air, with a built-in gas-water separator fitted with a stainless steel filter screen.
- Intelligent — Multi-channel temperature and pressure monitoring, real-time dew point display, automatic cumulative running time recording, compressor protection, and self-diagnosis with alarm code display.
- Eco-friendly — In compliance with the Montreal Protocol, all models adopt environment-friendly refrigerants (R134a, R410A, R407C) with zero damage to the atmosphere.
- Stable performance — Standardly equipped with a constant-pressure expansion valve and intelligent temperature controller. Laboratory-verified stable operation up to 65°C inlet air temperature and 42°C ambient temperature, with dual anti-freezing protection.
Working Principle

- Cooling Process — Heat exchange between refrigerant and compressed air cools the compressed air below the dew point temperature (typically 2–10°C) inside the evaporator.
- Condensation and Drainage — As the temperature drops, internal water vapor condenses into liquid droplets, which are discharged through the automatic drainage system.
- Function of Heat Exchanger — The precooler removes part of the moisture in advance; the cold-hot air heat exchanger improves energy utilization efficiency.
- Prevention of Secondary Condensation — Downstream pipeline temperature is kept above the dew point at the evaporator outlet to avoid secondary condensation.
Selection Specification Table
220/230V 50Hz 1-Phase
| Model | Max Processing Capacity (m³/min) | Input Power (kW) | Refrigerant | Air Connection Caliber | Weight (kg) | Dimension L*W*H (mm) |
|---|---|---|---|---|---|---|
| SCR-AD0012 | 1.2 | 0.37 | R134a | G3/4 | 34 | 505*380*665 |
| SCR-AD0024 | 2.4 | 0.52 | R134a | G3/4 | 42 | 545*410*725 |
| SCR-AD0036 | 3.6 | 0.73 | R410a | G1 | 50 | 665*520*850 |
| SCR-AD0065 | 6.5 | 1.26 | R410a | G1-1/2 | 63 | 725*540*950 |
| SCR-AD0085 | 8.5 | 1.87 | R410a | G2 | 73 | 795*590*990 |
| SCR-AD0110 | 11 | 2.43 | R410a | G2 | 85 | 795*590*990 |
| SCR-AD0135 | 13.5 | 2.63 | R410a | G2 | 94 | 825*610*1030 |
220/230V 60Hz 1-Phase
| Model | Max Processing Capacity (m³/min) | Input Power (kW) | Refrigerant | Air Connection Caliber | Weight (kg) | Dimension L*W*H (mm) |
|---|---|---|---|---|---|---|
| SCR-AD0012 | 1.2 | 0.39 | R134a | G3/4 | 34 | 505*380*665 |
| SCR-AD0024 | 2.4 | 0.55 | R134a | G3/4 | 42 | 545*410*725 |
| SCR-AD0036 | 3.6 | 0.76 | R410a | G1 | 50 | 665*520*850 |
| SCR-AD0065 | 6.5 | 1.32 | R410a | G1-1/2 | 63 | 725*540*950 |
| SCR-AD0085 | 8.5 | 1.96 | R410a | G2 | 73 | 795*590*990 |
| SCR-AD0110 | 11 | 2.55 | R410a | G2 | 85 | 795*590*990 |
| SCR-AD0135 | 13.5 | 2.76 | R410a | G2 | 94 | 825*610*1030 |
380/400/415V 50Hz 3-Phase
| Model | Max Processing Capacity (m³/min) | Input Power (kW) | Refrigerant | Air Connection Caliber | Weight (kg) | Dimension L*W*H (mm) |
|---|---|---|---|---|---|---|
| SCR-AD0170 | 17 | 3.8 | R407C | G2 | 180 | 1300*900*1100 |
| SCR-AD0230 | 23 | 4.9 | R407C | G2-1/2 | 210 | 1400*900*1160 |
| SCR-AD0270 | 27 | 6.3 | R407C | DN80 | 350 | 1400*950*1230 |
| SCR-AD0330 | 33 | 7.2 | R407C | DN80 | 420 | 1600*1000*1480 |
| SCR-AD0420 | 42 | 9.8 | R407C | DN100 | 550 | 1750*1100*1640 |
| SCR-AD0550 | 55 | 12.86 | R407C | DN100 | 680 | 1750*1150*1760 |
| SCR-AD0650 | 65 | 13.1 | R407C | DN125 | 780 | 2100*1450*1760 |
| SCR-AD0850 | 85 | 16 | R407C | DN125 | 920 | 2200*1500*1760 |
Notes:
- Customizable for different voltages and frequencies.
- Refrigerant R513A is available on request.
Selection Coefficient
Actual nominal volume flow rate (m³/min) = Selected processing capacity × KA × KB × KC (or KC')
Working Pressure Correction Factor (KA)
| Pressure MPa(g) | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 | 1.1 | 1.2 | 1.3 | 1.4 | 1.5 | 1.6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| KA | 0.55 | 0.72 | 0.8 | 0.9 | 1.0 | 1.02 | 1.06 | 1.1 | 1.15 | 1.18 | 1.22 | 1.25 | 1.28 | 1.299 |
Inlet Air Temperature Correction Factor (KB)
| Inlet Air Temp. °C | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| KB | 1.36 | 1.3 | 1.2 | 1.15 | 1.1 | 1.0 | 0.9 | 0.8 | 0.7 | 0.5 | 0.35 |
Ambient Temperature Correction Factor (KC)
| Ambient Temp. °C | 20 | 25 | 30 | 35 | 38 | 42 | 45 | 50 |
|---|---|---|---|---|---|---|---|---|
| KC | 1.45 | 1.35 | 1.22 | 1.1 | 1.05 | 1.0 | 0.75 | 0.6 |
Cooling Water Temperature Correction Factor (KC') — applies to water-cooled models
| Cooling Water Inlet Temp. °C | 10 | 15 | 20 | 25 | 28 | 32 | 35 | 38 |
|---|---|---|---|---|---|---|---|---|
| KC' | 1.45 | 1.35 | 1.22 | 1.1 | 1.05 | 1.0 | 0.75 | 0.6 |
*KC applies to air-cooled refrigerated dryers, and KC' applies to water-cooled refrigerated dryers.